Mi180 measures 6 different parameters: pH, ORP, EC, TDS (Total Dissolved Solids), percentage of NaCl and temperature in a variety of ranges.
pH calibration can be performed in 3 points selectable between 7 memorized buffers, to provide a very accurate calibration curve even when testing different samples, where very wide differences in pH can be found.
The auto-ranging feature for EC and TDS measurements automatically sets the resolution suitable to the tested sample.
All measurements can be temperature compensated at 20 or 25°C and the compensation coefficient is selectable by the user.
The automatic temperature compensation can also be disabled for measuring the actual conductivity value. The stability indicator on the LCD ensures accuracy. Conductivity readings are performed with the 4-ring probe supplied with the meter.
The GLP feature allows users to store and recall data on system status. PC compatible through an RS232 port or USB.
SPECIFICATIONS | |
pH Range | -2.00 to 16.00 pH; -2.000 to 16.000 pH |
mV Range | ±699.9 mV; ±2000 mV |
EC Range | 0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm uncompensed EC* |
TDS Range | 0.0 to 14.99 mg/l (ppm); 15.0 to 149.9 mg/l (ppm); 150 to 1499 mg/l (ppm); 1.50 to 14.99 g/l (ppt); 15.0 to 100.0 g/l (ppt); up to 400.0 g/l actual TDS* (with 0.80 factor) |
NaCl Range | 0.0 to 400.0% |
Temp Range | -20.0 to 120.0°C / -4.0 to 248.0°F |
pH Resolution | 0.01 pH; 0.001 pH |
mV Resolution | 0.1 mV; 1 mV |
EC Resolution | 0.01 µS/cm; 0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm; |
TDS Resolution | 0.01 mg/l; 0.1 mg/l; 1.0 mg/l; 0.01 g/l; 0.1 g/l |
NaCl Resolution | 0.1% |
Temp Resolution | 0.1°C / 0.1°F |
pH Accuracy | ±0.01 pH; ±0.002 pH |
mV Accuracy | ±0.2 mV; ±1 mV |
EC Accuracy | ±1% of reading ±(0.05 µS/cm or 1 digit) |
TDS Accuracy | ±1% of reading ±(0.03 ppm or 1 digit) |
NaCl Accuracy | ±1% of reading |
Temp Accuracy | ±0.4°C / ±0.8°F |
Rel mV Offset | ±2000 mV |
pH Calibration | 1, 2 or 3 points calibration, with 7 memorized buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45) |
EC Calibration | 1 point slope calibration with 6 memorized solutions: (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 µS/cm, 80.0 µS/cm, 111.8 mS/cm) |
NaCl Calibration | 1 point |
Temp Calibration | 2 point, at 0 and 50°C / 32 and 122°F |
Temperature Compensation | automatic or manual, from -20.0 to 120.0°C / -4.0 to 248.0°FF |
Temperature Coefficient | selectable from 0.00 to 6.00%/°C (EC and TDS only) |
pH Electrodes & Temp Probe | MA814DB/1 & MA917B/1 & MA831R (included) |
TDS Factor | 0.40 to 0.80 (default value is 0.50) |
Log on demand | up to 50 samples on each range (pH, mV, EC, TDS, NaCl) |
GLP | last pH, EC, NaCl calibration data |
PC Interface | RS232 / USB Opto-isolated |
Environment | 0 to 50°C / 32 to 122°F; max RH 95% |
Power supply | 12 VDC power adapter (included) |
Dimensions | 230 x 160 x 95 mm |
Weight | 0.9 kg |