PCV Serisi Mini Masaüstü Santrifüj

       


A versatile range of compact, modern benchtop centrifuges from Grant bio for a variety of biomedical, biochemical and life science applications requiring spinning or a combination of spinning and mixing for microtubes and microtitre plates.

Suitable for use in cold rooms and incubators (operating temperature range 4 to 40°C).

Combi-spin PCV-2400

A cost-effective fixed-speed combined centrifuge/vortex mixer for combined or independent centrifuge and mixing applications of microtubes and 0.2 ml microtube strips in low volume applications.

⇔ Centrifugation 2800rpm at 50Hz and 3500rpm at 60Hz
⇔ The vortex cup emerges through an opening in the closed lid, enabling individual tubes to be mixed while a full load of tubes is spinning.
⇔ Very simple to operate - use the left-hand button to select continuous or short spin. A safety interlock stops the rotor when the lid is opened to ensure you and your workplace remain safe.
⇔ The Combi-spin is supplied as standard with two interchangeable rotors for 12x1.5ml and 12x0.5ml + 12x0.2ml microtubes.
⇔ Optional accessory rotors - for 16 and 18 microtubes and for two 8-well 0.2.ml strips - allow for quick and easy changes of application.

Multi-spin PCV-6000

A variable-speed combined centrifuge/vortex mixer for programmed sequences of spin and mix operations or for independent centrifuging and vortex-mixing of multiple microtubes.

⇔ Centrifugation speed 1000 to 6000rpm
⇔ Multi-spin enables consecutive spin and mix phases of multiple tubes - tubes are loaded into the rotor for spinning and remain in position for vortex mixing, saving time and labour. In addition, lower reagent volumes can be used, providing a further saving.
⇔ Simple push-buttons and a clear 2-line LCD status display enable accurate and repeatable setting of spin and mix levels and times.
⇔ Spin and mix phases can be linked in sequences which can be repeated up to 999 times.
⇔ The Multi-spin™ is supplied as standard with two interchangeable rotors for 12 x 1.5 ml and 12 x 0.5 ml + 12 x 0.2 ml microtubes. Optional accessory rotors – for 
⇔ 16 and 18 microtubes and for two 8 well 0.2 ml strips – allow for quick and easy changes of application.
⇔ A safety interlock stops the rotor when the lid is opened to ensure you and your workplace remain safe.
⇔ Compact design and extremely quiet in operation - fits neatly and unobtrusively into the workspace

 
   
   

PCV-2400

PCV-600

Max RCF (bottom of tube) g-force                 g                                   700                               2350
Speed control range max. (centrifuges tubes)               rpm                            2800 at 50 Hz
                           3500 at 60 Hz
                              6000
Spin timer, with automatic switch-off                                        -----                   1 sec to 30 mins
Mix timer, with automatic switch-off                                        -----              1 to 20 sec (1 sec increment)
Vortex mixing intensity                                       -----                     soft, medium, hard
Number of tubes vortexing                               individual                 up to 12 simultaneously
Spin-mix-spin cycle regulation                                        -----                        1 to 999 cycles 
Time for completing the spin-mix-spin 100 microtubes                                 60 min                             10 min
  12 microtubes                                5-6 min                                1 min
Capacity  12 x 1.5/2.0 ml microtubes                                                                           
  12 x 0.5 ml plus 12 x 0.2 ml microtubes                                                                           
Display      2 line x 16 character LCD
Ambient temperature range °C                                                              4 to 40 


 

 

Diğer Ürünler
500 Internal Server Error

Internal Server Error

The server encountered an internal error or misconfiguration and was unable to complete your request.

Please contact the server administrator to inform of the time the error occurred and of anything you might have done that may have caused the error.

More information about this error may be available in the server error log.


Web Server at nittalab.com